BW Gas Alert MicroClip Confined Space 4 Gas Detector

BW Microclip & Bumpstation

Download Data Procedure
• Load Fleet Manager II (at least ver 2.1.2) software on PC and connect to Bump Station
• Powerup the Microclip and insert face down in Bay on the Doc Module. Note the serial number of the Microclip
• Press the Data Transfer On Button on the Doc Module
• In Fleet Manager II Select Tab Datalogs via Microclip
• Click Import (on LHS)
• Select GasAlertMicroclip> Appropriate Microclip> DatalogFile - Check this box
• Click Import (on RHS)
• Click Logs Results (on LSH)
• Select GasAlertMicroclip> Appropriate Microclip> DatalogFile
• You can apply a filter to remove some types of events if appropriate
• Click Export (On Bottom RHS)