Shutdowns often involve multiple crews, work areas, confined spaces and battery rooms, and confined spaces, making it important to plan gas detector hire before work begins.
One of the most common requests we receive is for a "4-gas detector". However, not all 4-gas detectors are the same, particularly when it comes to combustible gas monitoring.
1. Confirm the Gases of Concern
Before booking, identify the gases that could be present on site.
Our Honeywell BW Flex4 personal gas detectors monitor:
- Oxygen (O₂)
- Carbon Monoxide (CO)
- Hydrogen Sulphide (H₂S)
- Combustible gases (LEL)
The key difference between the two models is the combustible gas sensor.
| Model | LEL Sensor | Important to Know |
|---|---|---|
| Honeywell BW Flex4 | Catalytic | Suitable when hydrogen or acetylene may be present |
| Honeywell BW Flex4-IR | Infrared (IR) | Cannot detect hydrogen or acetylene |
A request for a "4-gas detector" doesn't tell us which LEL sensor your application requires. Let us know the specific combustible gases that may be present so we can confirm the right configuration.
2. Battery Rooms and Hydrogen Monitoring
If your shutdown includes battery rooms, charging areas or other locations where hydrogen may be present, it's important to mention this when arranging gas detector hire.
The Honeywell BW Flex4 uses a catalytic LEL sensor and can detect hydrogen and acetylene, while the BW Flex4-IR cannot. Simply requesting a "4-gas detector" may not provide enough information to determine the right configuration for your application.
3. How Many Detectors Do You Need?
Shutdown projects often involve multiple contractors and work fronts.
Providing the number of users, work areas and shifts helps ensure enough detectors are available for the duration of the shutdown.


4. Will You Need to Sample Spaces Before Entry?
Personal gas detectors monitor the atmosphere around the worker, but they are not always suitable for pre-entry testing.
If your shutdown includes confined spaces, tanks, pits or vessels, you may require a pumped gas detector such as:
- BW Ultra 4 Gas + CO₂
- BW Ultra 5 with Ammonia
- BW Ultra 4 Gas + PID
These detectors include an internal pump that can draw a sample from a distance, making them suitable for confined space atmospheric testing before entry.
5. Calibration and Fleet Management
For larger shutdowns involving multiple gas detectors, calibration and bump testing can become time-consuming if managed manually.
The IntelliDoX Bump and Calibration Station supports the Honeywell BW Flex4 and BW Flex4-IR, allowing automated bump testing, calibration and device management. This can help simplify detector preparation before deployment and support compliance requirements across larger shutdown projects.
What to Include in Your Enquiry
To help us recommend the right equipment, provide:
- Work areas
- Gases of concern
- Number of users
- Sampling requirements
- Hire dates
The more information we have upfront, the easier it is to confirm the right detector configuration and quantities for your shutdown.
Plan Ahead for a Successful Shutdown
Understanding the gases involved, whether combustible gas monitoring is required, and whether any spaces need to be sampled before entry helps ensure the right equipment is available when work starts.
If you're planning an upcoming shutdown, the TechRentals team can help determine the most suitable gas detector configuration based on your site conditions, monitoring requirements and project scope.
Frequently Asked Questions
Both detectors monitor oxygen (O₂), carbon monoxide (CO), hydrogen sulphide (H₂S) and combustible gases (LEL). The difference is the combustible gas sensor. The BW Flex4 uses a catalytic LEL sensor, while the BW Flex4-IR uses an infrared (IR) sensor. The BW Flex4-IR cannot detect hydrogen or acetylene, so it's important to confirm the gases of concern before selecting a detector.
If a space needs to be sampled before entry, a pumped gas detector may be required. Personal gas detectors monitor the atmosphere around the worker, whereas pumped detectors can draw air from a space before entry to assess atmospheric conditions. Let us know if your shutdown includes confined spaces, tanks, pits or vessels so we can discuss the most suitable option.
To help select the right equipment, provide the work areas, gases of concern, number of users, whether pre-entry sampling is required, and your hire dates. This allows us to confirm the most suitable detector configuration and ensure equipment availability for your shutdown.